Answer in brief
CVE-2024-34397 records a Unknown severity vulnerability in CISA ADP Vulnrichment. The current sources do not mark it as known exploited. The current feed maps n/a/n/a (generic), Siemens/RUGGEDCOM RST2428P (generic), Siemens/SCALANCE XCM-/XRM-/XCH-/XRH-300 family (generic), Siemens/SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
Analysis pending evidence review
HOL Guard separates source facts from reviewed analysis. See the methodology.
Answer in brief
CVE-2024-34397 records a Unknown severity vulnerability in CISA ADP Vulnrichment. The current sources do not mark it as known exploited. The current feed maps n/a/n/a (generic), Siemens/RUGGEDCOM RST2428P (generic), Siemens/SCALANCE XCM-/XRM-/XCH-/XRH-300 family (generic), Siemens/SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
Analysis pending evidence review
HOL Guard separates source facts from reviewed analysis. See the methodology.
A CVSS score is not reported in the current record. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.
Analysis status
Analysis pending evidence review
Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.
The current feed maps n/a/n/a (generic), Siemens/RUGGEDCOM RST2428P (generic), Siemens/SCALANCE XCM-/XRM-/XCH-/XRH-300 family (generic), Siemens/SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
| Package | Affected range | Fixed version |
|---|---|---|
| n/a/n/ageneric | n/a | Not reported |
| Siemens/RUGGEDCOM RST2428Pgeneric | >=0 <V3.1 | V3.1 |
| Siemens/SCALANCE XCM-/XRM-/XCH-/XRH-300 familygeneric | >=0 <V3.1 | V3.1 |
| Siemens/SIMATIC S7-1500 CPU 1518-4 PN/DP MFPgeneric | >=V3.1.5 <* | * |
| Siemens/SIMATIC S7-1500 CPU 1518F-4 PN/DP MFPgeneric | >=V3.1.5 <* | * |
| Siemens/SIPLUS S7-1500 CPU 1518-4 PN/DP MFPgeneric | >=V3.1.5 <* | * |
Published upstream
May 7, 2024
Evidence: source:cvelist:source_dates:source-dates:recordSource modified
Jul 14, 2026
Evidence: source:cvelist:source_dates:source-dates:recordFirst seen by HOL
Aug 6, 2026
An issue was discovered in GNOME GLib before 2.78.5, and 2.79.x and 2.80.x before 2.80.1. When a GDBus-based client subscribes to signals from a trusted system service such as NetworkManager on a shared computer, other users of the same computer can send spoofed D-Bus signals that the GDBus-based client will wrongly interpret as having been sent by the trusted system service. This could lead to the GDBus-based client behaving incorrectly, with an application-dependent impact.
Quoted source text, attributed separately from HOL analysis.
A CVSS score is not reported in the current record. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.
Analysis status
Analysis pending evidence review
Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.
The current feed maps n/a/n/a (generic), Siemens/RUGGEDCOM RST2428P (generic), Siemens/SCALANCE XCM-/XRM-/XCH-/XRH-300 family (generic), Siemens/SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
| Package | Affected range | Fixed version |
|---|---|---|
| n/a/n/ageneric | n/a | Not reported |
| Siemens/RUGGEDCOM RST2428Pgeneric | >=0 <V3.1 | V3.1 |
| Siemens/SCALANCE XCM-/XRM-/XCH-/XRH-300 familygeneric | >=0 <V3.1 | V3.1 |
| Siemens/SIMATIC S7-1500 CPU 1518-4 PN/DP MFPgeneric | >=V3.1.5 <* | * |
| Siemens/SIMATIC S7-1500 CPU 1518F-4 PN/DP MFPgeneric | >=V3.1.5 <* | * |
| Siemens/SIPLUS S7-1500 CPU 1518-4 PN/DP MFPgeneric | >=V3.1.5 <* | * |
Published upstream
May 7, 2024
Evidence: source:cvelist:source_dates:source-dates:recordSource modified
Jul 14, 2026
Evidence: source:cvelist:source_dates:source-dates:recordFirst seen by HOL
Aug 6, 2026
An issue was discovered in GNOME GLib before 2.78.5, and 2.79.x and 2.80.x before 2.80.1. When a GDBus-based client subscribes to signals from a trusted system service such as NetworkManager on a shared computer, other users of the same computer can send spoofed D-Bus signals that the GDBus-based client will wrongly interpret as having been sent by the trusted system service. This could lead to the GDBus-based client behaving incorrectly, with an application-dependent impact.
Quoted source text, attributed separately from HOL analysis.