HOL LogoGuard

Explore HOL

  • HOL home
  • AI agent registry
  • AI plugins
  • Open standards
  • HOL members
  • Sponsor HOL
  • Advertise with HOL

Guard product

  • Guard overviewLocal security and control for AI agents and the tools they use.
  • FeaturesRuntime protection, policy routing, review, and evidence.

Explore Guard

  • Product previewWalk through Guard surfaces in read-only demo mode.
  • ComparisonCompare Guard with native controls and AI security vendors.

AI tools

  • All AI toolsEvery supported AI tool and how Guard applies policy to it.
  • Codex
  • Claude Code
  • Cursor
  • Antigravity CLI
  • OpenCode
  • Hermes
  • OpenClaw
  • GitHub Copilot CLI
  • Antigravity
  • Kimi
  • Grok
  • Pi / Oh My Pi
  • Zcode

Extensions

  • All extensionsBrowse command and MCP coverage with owners and stated limits.
  • Command coverageShell command protection across clouds, databases, backups, and packages.
  • MCP server coverageSee how Guard maps risk state across MCP tools and servers.
  • Core safetyThe safety floor listings that ship with Guard.
  • Data and resilienceBackup and storage command protection.
  • Cloud and infrastructureAWS, Azure, GCP, Kubernetes, and more.

Security

  • AI security hubSecurity research, advisories, and agent safety coverage.
  • AI tool securitySecurity profiles for each supported coding agent.
  • Safe labsHands-on attack simulations with safe boundaries.
  • Redacted warningsReal blocked actions with sensitive details removed.
  • AdvisoriesCoordinated disclosure reports for AI tooling.
  • Active CVEsSearch active CVEs affecting AI tooling.

Learn

  • Security guidesPractical guides for securing AI agent workflows.
  • DocsInstall, configure, and operate Guard with confidence.
  • ResearchPublished security research, benchmarks, and methodology.

Community

  • ReleasesVersion history, shipped changes and upgrade notes.
  • ContributorsThe people and contributions behind HOL Guard.
  • AffiliatesShare Guard with your audience and earn from referrals.
  • SponsorFund agreed research, implementation and shared testing through the HOL Partner Program.
  • AdvertiseCompare README logo placements, previews and monthly prices, or promote a plugin or extension.
PricingEnterpriseOpen AppInstall Guard
  1. Guard
  2. Security
  3. CVEs
  4. CVE 2024 56182 cisa adp vulnrichment
HOL Guard

Public security guidance for teams protecting AI harnesses, MCP servers, skills, prompts, and local tool execution.

Install Guard

AI Security

  • Prompt injection
  • MCP security
  • OWASP MCP mapping
  • Supply chain

Resources

  • Trust packet
  • Harness setup
  • Redacted warnings
  • Safe labs

Product

  • Install Guard
  • Pricing
  • Open dashboard
Guard
  • Guard Overview
  • Releases
  • Contributors
  • Install Guard
  • Pricing
Docs
  • Documentation Index
  • Developer Hub
  • API Reference
  • Root OpenAPI
  • Registry OpenAPI
  • Run in Postman
  • Standards
  • Submit ERC-8004 Contract
  • Feature Your Agent
Best Plugins
  • Browse Plugins
  • Plugin Launches
  • Best Claude Plugins
  • Best Codex Plugins
  • Best Grok Plugins
  • Best Kimi Plugins
  • Best DeepSeek Plugins
  • Best Antigravity Plugins
  • Best MCP Servers
  • Best Cursor Plugins
  • Best OpenCode Plugins
Best Agents
  • Best ERC-8004 Agents
  • Best Virtuals Agents
  • Best MCP Servers
  • Best A2A Agents
  • Best x402 Payable
  • All Categories
Community
  • Telegram
  • X
More
  • About HOL
  • Sponsor
  • Advertise
  • Contact
  • Blog
  • GitHub
  • Privacy
  • Terms of Service
Settings

Copyright © 2026 HOL DAO LLC. All rights reserved.

Back to active CVEs
High · CVSS 8.2CVE-2024-56182

CISA ADP VulnrichmentCVE-2024-56182

Answer in brief

CVE-2024-56182 records a High severity (CVSS 8.2) vulnerability in CISA ADP Vulnrichment. The current sources do not mark it as known exploited. The current feed maps Siemens/SIMATIC Field PG M5 (generic), Siemens/SIMATIC Field PG M6 (generic), Siemens/SIMATIC IPC127E (generic), Siemens/SIMATIC IPC227E (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.

Analysis pending evidence review

HOL Guard separates source facts from reviewed analysis. See the methodology.

Published Mar 11, 2025Updated Sep 8, 2026Source checked Oct 23, 2026First seen by HOL Sep 8, 2026Material review Sep 8, 2026
Upstream Advisory

Key facts

Risk
High · CVSS 8.2
Exploitation
Not marked as known exploited
Affected software
32 mapped packages or products
Fix availability
Available

Why this deserves its current priority

CVSS is 8.2. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.

Analysis status

Analysis pending evidence review

Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.

Affected scope and exposure questions

The current feed maps Siemens/SIMATIC Field PG M5 (generic), Siemens/SIMATIC Field PG M6 (generic), Siemens/SIMATIC IPC127E (generic), Siemens/SIMATIC IPC227E (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.

Mapped affected packages and fixed versions
PackageAffected rangeFixed version
Siemens/SIMATIC Field PG M5generic>=0 <**
Siemens/SIMATIC Field PG M6generic>=0 <V26.01.12V26.01.12
Siemens/SIMATIC IPC127Egeneric>=0 <V27.01.11V27.01.11
Siemens/SIMATIC IPC227Egeneric>=0 <**
Siemens/SIMATIC IPC227Ggeneric>=0 <V28.01.14V28.01.14
Siemens/SIMATIC IPC277Egeneric>=0 <**
Siemens/SIMATIC IPC277Ggeneric>=0 <V28.01.14V28.01.14
Siemens/SIMATIC IPC277G PROgeneric>=0 <V28.01.14V28.01.14
Siemens/SIMATIC IPC3000 SMART V3generic>=0 <**
Siemens/SIMATIC IPC327Ggeneric>=0 <V28.01.14V28.01.14
Siemens/SIMATIC IPC347Ggeneric>=0 <**
Siemens/SIMATIC IPC377Ggeneric>=0 <V28.01.14V28.01.14
Siemens/SIMATIC IPC427Egeneric>=0 <V21.01.21V21.01.21
Siemens/SIMATIC IPC477Egeneric>=0 <V21.01.21V21.01.21
Siemens/SIMATIC IPC477E PROgeneric>=0 <V21.01.21V21.01.21
Siemens/SIMATIC IPC527Ggeneric>=0 <**
Siemens/SIMATIC IPC627Egeneric>=0 <V25.02.15V25.02.15
Siemens/SIMATIC IPC647Egeneric>=0 <V25.02.15V25.02.15
Siemens/SIMATIC IPC677Egeneric>=0 <V25.02.15V25.02.15
Siemens/SIMATIC IPC847Egeneric>=0 <V25.02.15V25.02.15
Siemens/SIMATIC IPC BX-21Ageneric>=0 <V31.01.07V31.01.07
Siemens/SIMATIC IPC BX-32Ageneric>=0 <V29.01.07V29.01.07
Siemens/SIMATIC IPC BX-39Ageneric>=0 <V29.01.07V29.01.07
Siemens/SIMATIC IPC BX-59Ageneric>=0 <V32.01.04V32.01.04
Siemens/SIMATIC IPC PX-32Ageneric>=0 <V29.01.07V29.01.07
Siemens/SIMATIC IPC PX-39Ageneric>=0 <V29.01.07V29.01.07
Siemens/SIMATIC IPC PX-39A PROgeneric>=0 <V29.01.07V29.01.07
Siemens/SIMATIC IPC RC-543Ageneric>=0 <V36.01.03V36.01.03
Siemens/SIMATIC IPC RC-543Bgeneric>=0 <V35.01.12V35.01.12
Siemens/SIMATIC IPC RW-543Ageneric>=0 <V1.1.4V1.1.4
Siemens/SIMATIC IPC RW-543Bgeneric>=0 <V35.02.10V35.02.10
Siemens/SIMATIC ITP1000generic>=0 <**

Recommended response

  1. 1Check inventory. Check lockfiles and deployed manifests for Siemens/SIMATIC Field PG M5, Siemens/SIMATIC Field PG M6, Siemens/SIMATIC IPC127E.
  2. 2Review the reported fix. Update Siemens/SIMATIC Field PG M5 to *; Siemens/SIMATIC Field PG M6 to V26.01.12; Siemens/SIMATIC IPC127E to V27.01.11; Siemens/SIMATIC IPC227E to *; Siemens/SIMATIC IPC227G to V28.01.14; Siemens/SIMATIC IPC277E to *; Siemens/SIMATIC IPC277G to V28.01.14; Siemens/SIMATIC IPC277G PRO to V28.01.14; Siemens/SIMATIC IPC3000 SMART V3 to *; Siemens/SIMATIC IPC327G to V28.01.14; Siemens/SIMATIC IPC347G to *; Siemens/SIMATIC IPC377G to V28.01.14; Siemens/SIMATIC IPC427E to V21.01.21; Siemens/SIMATIC IPC477E to V21.01.21; Siemens/SIMATIC IPC477E PRO to V21.01.21; Siemens/SIMATIC IPC527G to *; Siemens/SIMATIC IPC627E to V25.02.15; Siemens/SIMATIC IPC647E to V25.02.15; Siemens/SIMATIC IPC677E to V25.02.15; Siemens/SIMATIC IPC847E to V25.02.15; Siemens/SIMATIC IPC BX-21A to V31.01.07; Siemens/SIMATIC IPC BX-32A to V29.01.07; Siemens/SIMATIC IPC BX-39A to V29.01.07; Siemens/SIMATIC IPC BX-59A to V32.01.04; Siemens/SIMATIC IPC PX-32A to V29.01.07; Siemens/SIMATIC IPC PX-39A to V29.01.07; Siemens/SIMATIC IPC PX-39A PRO to V29.01.07; Siemens/SIMATIC IPC RC-543A to V36.01.03; Siemens/SIMATIC IPC RC-543B to V35.01.12; Siemens/SIMATIC IPC RW-543A to V1.1.4; Siemens/SIMATIC IPC RW-543B to V35.02.10; Siemens/SIMATIC ITP1000 to * if you use the affected versions. Test the change in a non-production environment first.

Evidence timeline and material changes

  1. Published upstream

    Mar 11, 2025

    Evidence: source:cvelist:source_dates:source-dates:record
  2. Source modified

    Sep 8, 2026

    Evidence: source:cvelist:source_dates:source-dates:record
  3. First seen by HOL

    Sep 8, 2026

Sources and claim methodology

  • Source referencecert-portal.siemens.com
Upstream source description

A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC Field PG M6 (All versions < V26.01.12), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions < V36.01.03), SIMATIC IPC RC-543B (All versions < V35.01.12), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC RW-543B (All versions < V35.02.10), SIMATIC IPC127E (All versions < V27.01.11), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATIC IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions < V21.01.21), SIMATIC IPC477E (All versions < V21.01.21), SIMATIC IPC477E PRO (All versions < V21.01.21), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions < V25.02.15), SIMATIC IPC647E (All versions < V25.02.15), SIMATIC IPC677E (All versions < V25.02.15), SIMATIC IPC847E (All versions < V25.02.15), SIMATIC ITP1000 (All versions). The affected devices have insufficient protection mechanism for the EFI(Extensible Firmware Interface) variables stored on the device. This could allow an authenticated attacker to disable the BIOS password without proper authorization by directly communicate with the flash controller.

Quoted source text, attributed separately from HOL analysis.

Related CVEs

  • baserCMS: Public Web API mail-form submission bypasses image CAPTCHAAlso CWE-693

Record context

Vulnerability class
Vulnerability
EPSS
Not reported
CWE IDs
CWE-693
Source
CVE List V5
Source checked
Oct 23, 2026
References
1 linked source
Open source record