Answer in brief
CVE-2025-30033 records a Unknown severity vulnerability in CISA ADP Vulnrichment. The current sources do not mark it as known exploited. The current feed maps Siemens/Automation License Manager V6.0 (generic), Siemens/Automation License Manager V6.2 (generic), Siemens/CEMAT V10.0 (generic), Siemens/CP PtP Param configuring interface (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
Analysis pending evidence review
HOL Guard separates source facts from reviewed analysis. See the methodology.
A CVSS score is not reported in the current record. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.
Analysis status
Analysis pending evidence review
Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.
The current feed maps Siemens/Automation License Manager V6.0 (generic), Siemens/Automation License Manager V6.2 (generic), Siemens/CEMAT V10.0 (generic), Siemens/CP PtP Param configuring interface (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
| Package | Affected range | Fixed version |
|---|---|---|
| Siemens/Automation License Manager V6.0generic | >=0 <* | * |
| Siemens/Automation License Manager V6.2generic | >=0 <V6.2 Upd3 | V6.2 Upd3 |
| Siemens/CEMAT V10.0generic | >=0 <* | * |
| Siemens/CP PtP Param configuring interfacegeneric | >=0 <* | * |
| Siemens/Create MyConfig (CMC)generic | >=0 <V6.9 | V6.9 |
| Siemens/Energy Support Library (EnSL)generic | >=0 <* | * |
| Siemens/FM Configuration Packagegeneric | >=0 <* | * |
| Siemens/Modular PID CTRL Toolgeneric | >=0 <* | * |
| Siemens/MultiFieldbus Configuration Tool (MFCT)generic | >=0 <V1.5.5.0 | V1.5.5.0 |
| Siemens/OpenPCS 7 V10.0generic | >=0 <* | * |
| Siemens/OpenPCS 7 V9.1generic | >=0 <* | * |
| Siemens/Siemens Network Planner (SINETPLAN)generic | >=0 <* | * |
| Siemens/SIMATIC Automation Toolgeneric | >=0 <V5.0 SP4 | V5.0 SP4 |
| Siemens/SIMATIC Automation Tool SDK Windowsgeneric | >=0 <V5.0 SP4 | V5.0 SP4 |
| Siemens/SIMATIC BATCH V10.0generic | >=0 <* | * |
| Siemens/SIMATIC BATCH V9.1generic | >=0 <* | * |
| Siemens/SIMATIC Control Function Library (CFL) V1.xgeneric | >=0 <* | * |
| Siemens/SIMATIC Control Function Library (CFL) V2.xgeneric | >=0 <* | * |
| Siemens/SIMATIC Control Function Library (CFL) V3.xgeneric | >=0 <V3.1.0.2 | V3.1.0.2 |
| Siemens/SIMATIC Control Function Library (CFL) V4.xgeneric | >=0 <V4.1 | V4.1 |
| Siemens/SIMATIC D7-SYSgeneric | >=0 <V10.0 SP1 | V10.0 SP1 |
| Siemens/SIMATIC eaSie Core Packagegeneric | >=0 <* | * |
| Siemens/SIMATIC eaSie Document Skillsgeneric | >=0 <* | * |
| Siemens/SIMATIC eaSie PCS 7 Skill Packagegeneric | >=0 <* | * |
| Siemens/SIMATIC eaSie Workflow Skillsgeneric | >=0 <* | * |
| Siemens/SIMATIC Energy Suite V17generic | >=0 <* | * |
| Siemens/SIMATIC Energy Suite V18generic | >=0 <* | * |
| Siemens/SIMATIC Energy Suite V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/SIMATIC Logon V1.6generic | >=0 <* | * |
| Siemens/SIMATIC Logon V2.0generic | >=0 <V2.0 Upd3 | V2.0 Upd3 |
| Siemens/SIMATIC Management Agentgeneric | >=0 <V9.1 SP1 Upd8 | V9.1 SP1 Upd8 |
| Siemens/SIMATIC Management Consolegeneric | >=0 <V9.1 SP1 Upd8 | V9.1 SP1 Upd8 |
| Siemens/SIMATIC MTP CREATOR V2.xgeneric | >=0 <V2.1 | V2.1 |
| Siemens/SIMATIC MTP CREATOR V3.xgeneric | >=0 <* | * |
| Siemens/SIMATIC MTP CREATOR V4.xgeneric | >=0 <V4.1.0.1 | V4.1.0.1 |
| Siemens/SIMATIC MTP CREATOR V5.xgeneric | >=0 <V5.0.0.1 | V5.0.0.1 |
| Siemens/SIMATIC MTP Integrator V1.xgeneric | >=0 <* | * |
| Siemens/SIMATIC MTP Integrator V2.xgeneric | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V16generic | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V17generic | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V18generic | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V19generic | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V20generic | >=0 <V20.0 Update 1 | V20.0 Update 1 |
| Siemens/SIMATIC ODK 1500Sgeneric | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Faceplates V9.1generic | >=0 <V9.1 SP2 Upd4 | V9.1 SP2 Upd4 |
| Siemens/SIMATIC PCS 7 Advanced Process Functions V2.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Functions V2.2generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Graphics V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Graphics V9.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Library V9.1generic | >=0 <V9.1 SP2 Upd6 | V9.1 SP2 Upd6 |
| Siemens/SIMATIC PCS 7 Basis Faceplates V9.1generic | >=0 <V9.1 SP2 Upd2 | V9.1 SP2 Upd2 |
| Siemens/SIMATIC PCS 7 Basis Library V10.0generic | >=0 <V10.0 SP1 Upd2 | V10.0 SP1 Upd2 |
| Siemens/SIMATIC PCS 7 Basis Library V9.1generic | >=0 <V9.1 SP2 Upd8 | V9.1 SP2 Upd8 |
| Siemens/SIMATIC PCS 7 Industry Library V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Industry Library V9.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Industry Library V9.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Logic Matrix V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Logic Matrix V9.1generic | >=0 <V9.1 Upd8 | V9.1 Upd8 |
| Siemens/SIMATIC PCS 7 MPC Configuratorgeneric | >=0 <* | * |
| Siemens/SIMATIC PCS 7/OPEN OS V9.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 PowerControlgeneric | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Standard Chemical Library V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Standard Chemical Library V9.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 TeleControlgeneric | >=0 <* | * |
| Siemens/SIMATIC PCS 7 V10.0generic | >=0 <V10.0 SP1 UC01 | V10.0 SP1 UC01 |
| Siemens/SIMATIC PCS 7 V9.1generic | >=0 <V9.1 SP1 UC08 | V9.1 SP1 UC08 |
| Siemens/SIMATIC PCS neo V5.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS neo V6.0generic | >=0 <V6.0 SP1 | V6.0 SP1 |
| Siemens/SIMATIC PDM Maintenance Station V5.0generic | >=0 <* | * |
| Siemens/SIMATIC PDM V9.2generic | >=0 <* | * |
| Siemens/SIMATIC PDM V9.3generic | >=0 <V9.3 SP1 Upd2 | V9.3 SP1 Upd2 |
| Siemens/SIMATIC Process Function Library (PFL) V4.0generic | >=0 <* | * |
| Siemens/SIMATIC Process Historian 2020generic | >=0 <* | * |
| Siemens/SIMATIC Process Historian 2022generic | >=0 <* | * |
| Siemens/SIMATIC Process Historian 2024generic | >=0 <V2024 SP1 Upd2 | V2024 SP1 Upd2 |
| Siemens/SIMATIC ProSave V17generic | >=0 <V17 Update 9 | V17 Update 9 |
| Siemens/SIMATIC ProSave V18generic | >=0 <* | * |
| Siemens/SIMATIC ProSave V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/SIMATIC ProSave V20generic | >=0 <* | * |
| Siemens/SIMATIC Route Control V10.0generic | >=0 <* | * |
| Siemens/SIMATIC Route Control V9.1generic | >=0 <* | * |
| Siemens/SIMATIC S7-1500 Software Controller V2generic | >=0 <* | * |
| Siemens/SIMATIC S7-1500 Software Controller V3generic | >=0 <V31.1.5 | V31.1.5 |
| Siemens/SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)generic | >=0 <V4.0.1 | V4.0.1 |
| Siemens/SIMATIC S7 F Systems V6.3generic | >=0 <* | * |
| Siemens/SIMATIC S7 F Systems V6.4generic | >=0 <* | * |
| Siemens/SIMATIC S7-PCTgeneric | >=0 <V3.5 SP4 Update 1 | V3.5 SP4 Update 1 |
| Siemens/SIMATIC S7-PLCSIM Advancedgeneric | >=0 <V7.0 Update 1 | V7.0 Update 1 |
| Siemens/SIMATIC S7-PLCSIM V17generic | >=0 <* | * |
| Siemens/SIMATIC S7-PLCSIM V18generic | >=0 <* | * |
| Siemens/SIMATIC S7-PLCSIM V19generic | >=0 <* | * |
| Siemens/SIMATIC S7-PLCSIM V20generic | >=0 <V20 Update 1 | V20 Update 1 |
| Siemens/SIMATIC Safety Matrixgeneric | >=0 <* | * |
| Siemens/SIMATIC STEP 7 CFC V19generic | >=0 <* | * |
| Siemens/SIMATIC STEP 7 CFC V20generic | >=0 <* | * |
| Siemens/SIMATIC STEP 7 V5.7generic | >=0 <* | * |
| Siemens/SIMATIC Targetgeneric | >=0 <V6.0 SP3 | V6.0 SP3 |
| Siemens/SIMATIC WinCC flexible ESgeneric | >=0 <* | * |
| Siemens/SIMATIC WinCC Runtime Advancedgeneric | >=0 <V17 Update 9 | V17 Update 9 |
| Siemens/SIMATIC WinCC Runtime Professionalgeneric | >=0 <V21 | V21 |
| Siemens/SIMATIC WinCC Runtime Professional V20generic | >=0 <* | * |
| Siemens/SIMATIC WinCC TeleControlgeneric | >=0 <* | * |
| Siemens/SIMATIC WinCC Unified Line Coordinationgeneric | >=0 <V20 | V20 |
| Siemens/SIMATIC WinCC Unified PC Runtime V18generic | >=0 <* | * |
| Siemens/SIMATIC WinCC Unified PC Runtime V19generic | >=0 <* | * |
| Siemens/SIMATIC WinCC Unified PC Runtime V20generic | >=0 <* | * |
| Siemens/SIMATIC WinCC Unified Sequencegeneric | >=0 <V20 | V20 |
| Siemens/SIMATIC WinCC V7.5generic | >=0 <V7.5 SP2 Update 20 | V7.5 SP2 Update 20 |
| Siemens/SIMATIC WinCC V8.0generic | >=0 <V8.0 Update 8 | V8.0 Update 8 |
| Siemens/SIMATIC WinCC V8.1generic | >=0 <V8.1 Update 3 | V8.1 Update 3 |
| Siemens/SIMATIC WinCC Visualization Architect (SiVArc) V17generic | >=0 <V17 Update 9 | V17 Update 9 |
| Siemens/SIMATIC WinCC Visualization Architect (SiVArc) V18generic | >=0 <* | * |
| Siemens/SIMATIC WinCC Visualization Architect (SiVArc) V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/SIMATIC WinCC Visualization Architect (SiVArc) V20generic | >=0 <V20 Update 3 | V20 Update 3 |
| Siemens/SIMIT Rapid Testergeneric | >=0 <* | * |
| Siemens/SIMIT Simulation Platformgeneric | >=0 <* | * |
| Siemens/SINAMICS Startdrive V17generic | >=0 <* | * |
| Siemens/SINAMICS Startdrive V18generic | >=0 <* | * |
| Siemens/SINAMICS Startdrive V19generic | >=0 <* | * |
| Siemens/SINAMICS Startdrive V20generic | >=0 <* | * |
| Siemens/SINEC NMSgeneric | >=0 <V4.0 | V4.0 |
| Siemens/SINEMA Remote Connect Clientgeneric | >=0 <* | * |
| Siemens/SITRANSgeneric | >=0 <* | * |
| Siemens/Standard PID CTRL Toolgeneric | >=0 <* | * |
| Siemens/TeleControl Server Basic V3.1generic | >=0 <V3.1.2.2 | V3.1.2.2 |
| Siemens/TIA Administratorgeneric | >=0 <V3.0.6 | V3.0.6 |
| Siemens/TIA Portal Cloud Connectorgeneric | >=0 <V2.3 | V2.3 |
| Siemens/TIA Portal Test Suite V17generic | >=0 <* | * |
| Siemens/TIA Portal Test Suite V18generic | >=0 <* | * |
| Siemens/TIA Portal Test Suite V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/TIA Portal Test Suite V20generic | >=0 <V20 Update 3 | V20 Update 3 |
| Siemens/TIA Project-Servergeneric | >=0 <V2.2 | V2.2 |
| Siemens/TIA Project-Server V17generic | >=0 <* | * |
| Siemens/Totally Integrated Automation Portal (TIA Portal) V17generic | >=0 <V17 Update 9 | V17 Update 9 |
| Siemens/Totally Integrated Automation Portal (TIA Portal) V18generic | >=0 <* | * |
| Siemens/Totally Integrated Automation Portal (TIA Portal) V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/Totally Integrated Automation Portal (TIA Portal) V20generic | >=0 <V20 Update 4 | V20 Update 4 |
| Siemens/WinCC Panel Image Setupgeneric | >=0 <V17 Update 9 | V17 Update 9 |
Published upstream
Aug 12, 2025
Evidence: source:cvelist:source_dates:source-dates:recordSource modified
Aug 11, 2026
Evidence: source:cvelist:source_dates:source-dates:recordFirst seen by HOL
Aug 11, 2026
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
Quoted source text, attributed separately from HOL analysis.
Answer in brief
CVE-2025-30033 records a Unknown severity vulnerability in CISA ADP Vulnrichment. The current sources do not mark it as known exploited. The current feed maps Siemens/Automation License Manager V6.0 (generic), Siemens/Automation License Manager V6.2 (generic), Siemens/CEMAT V10.0 (generic), Siemens/CP PtP Param configuring interface (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
Analysis pending evidence review
HOL Guard separates source facts from reviewed analysis. See the methodology.
A CVSS score is not reported in the current record. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.
Analysis status
Analysis pending evidence review
Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.
The current feed maps Siemens/Automation License Manager V6.0 (generic), Siemens/Automation License Manager V6.2 (generic), Siemens/CEMAT V10.0 (generic), Siemens/CP PtP Param configuring interface (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
| Package | Affected range | Fixed version |
|---|---|---|
| Siemens/Automation License Manager V6.0generic | >=0 <* | * |
| Siemens/Automation License Manager V6.2generic | >=0 <V6.2 Upd3 | V6.2 Upd3 |
| Siemens/CEMAT V10.0generic | >=0 <* | * |
| Siemens/CP PtP Param configuring interfacegeneric | >=0 <* | * |
| Siemens/Create MyConfig (CMC)generic | >=0 <V6.9 | V6.9 |
| Siemens/Energy Support Library (EnSL)generic | >=0 <* | * |
| Siemens/FM Configuration Packagegeneric | >=0 <* | * |
| Siemens/Modular PID CTRL Toolgeneric | >=0 <* | * |
| Siemens/MultiFieldbus Configuration Tool (MFCT)generic | >=0 <V1.5.5.0 | V1.5.5.0 |
| Siemens/OpenPCS 7 V10.0generic | >=0 <* | * |
| Siemens/OpenPCS 7 V9.1generic | >=0 <* | * |
| Siemens/Siemens Network Planner (SINETPLAN)generic | >=0 <* | * |
| Siemens/SIMATIC Automation Toolgeneric | >=0 <V5.0 SP4 | V5.0 SP4 |
| Siemens/SIMATIC Automation Tool SDK Windowsgeneric | >=0 <V5.0 SP4 | V5.0 SP4 |
| Siemens/SIMATIC BATCH V10.0generic | >=0 <* | * |
| Siemens/SIMATIC BATCH V9.1generic | >=0 <* | * |
| Siemens/SIMATIC Control Function Library (CFL) V1.xgeneric | >=0 <* | * |
| Siemens/SIMATIC Control Function Library (CFL) V2.xgeneric | >=0 <* | * |
| Siemens/SIMATIC Control Function Library (CFL) V3.xgeneric | >=0 <V3.1.0.2 | V3.1.0.2 |
| Siemens/SIMATIC Control Function Library (CFL) V4.xgeneric | >=0 <V4.1 | V4.1 |
| Siemens/SIMATIC D7-SYSgeneric | >=0 <V10.0 SP1 | V10.0 SP1 |
| Siemens/SIMATIC eaSie Core Packagegeneric | >=0 <* | * |
| Siemens/SIMATIC eaSie Document Skillsgeneric | >=0 <* | * |
| Siemens/SIMATIC eaSie PCS 7 Skill Packagegeneric | >=0 <* | * |
| Siemens/SIMATIC eaSie Workflow Skillsgeneric | >=0 <* | * |
| Siemens/SIMATIC Energy Suite V17generic | >=0 <* | * |
| Siemens/SIMATIC Energy Suite V18generic | >=0 <* | * |
| Siemens/SIMATIC Energy Suite V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/SIMATIC Logon V1.6generic | >=0 <* | * |
| Siemens/SIMATIC Logon V2.0generic | >=0 <V2.0 Upd3 | V2.0 Upd3 |
| Siemens/SIMATIC Management Agentgeneric | >=0 <V9.1 SP1 Upd8 | V9.1 SP1 Upd8 |
| Siemens/SIMATIC Management Consolegeneric | >=0 <V9.1 SP1 Upd8 | V9.1 SP1 Upd8 |
| Siemens/SIMATIC MTP CREATOR V2.xgeneric | >=0 <V2.1 | V2.1 |
| Siemens/SIMATIC MTP CREATOR V3.xgeneric | >=0 <* | * |
| Siemens/SIMATIC MTP CREATOR V4.xgeneric | >=0 <V4.1.0.1 | V4.1.0.1 |
| Siemens/SIMATIC MTP CREATOR V5.xgeneric | >=0 <V5.0.0.1 | V5.0.0.1 |
| Siemens/SIMATIC MTP Integrator V1.xgeneric | >=0 <* | * |
| Siemens/SIMATIC MTP Integrator V2.xgeneric | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V16generic | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V17generic | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V18generic | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V19generic | >=0 <* | * |
| Siemens/SIMATIC NET PC Software V20generic | >=0 <V20.0 Update 1 | V20.0 Update 1 |
| Siemens/SIMATIC ODK 1500Sgeneric | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Faceplates V9.1generic | >=0 <V9.1 SP2 Upd4 | V9.1 SP2 Upd4 |
| Siemens/SIMATIC PCS 7 Advanced Process Functions V2.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Functions V2.2generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Graphics V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Graphics V9.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Advanced Process Library V9.1generic | >=0 <V9.1 SP2 Upd6 | V9.1 SP2 Upd6 |
| Siemens/SIMATIC PCS 7 Basis Faceplates V9.1generic | >=0 <V9.1 SP2 Upd2 | V9.1 SP2 Upd2 |
| Siemens/SIMATIC PCS 7 Basis Library V10.0generic | >=0 <V10.0 SP1 Upd2 | V10.0 SP1 Upd2 |
| Siemens/SIMATIC PCS 7 Basis Library V9.1generic | >=0 <V9.1 SP2 Upd8 | V9.1 SP2 Upd8 |
| Siemens/SIMATIC PCS 7 Industry Library V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Industry Library V9.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Industry Library V9.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Logic Matrix V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Logic Matrix V9.1generic | >=0 <V9.1 Upd8 | V9.1 Upd8 |
| Siemens/SIMATIC PCS 7 MPC Configuratorgeneric | >=0 <* | * |
| Siemens/SIMATIC PCS 7/OPEN OS V9.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 PowerControlgeneric | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Standard Chemical Library V10.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 Standard Chemical Library V9.1generic | >=0 <* | * |
| Siemens/SIMATIC PCS 7 TeleControlgeneric | >=0 <* | * |
| Siemens/SIMATIC PCS 7 V10.0generic | >=0 <V10.0 SP1 UC01 | V10.0 SP1 UC01 |
| Siemens/SIMATIC PCS 7 V9.1generic | >=0 <V9.1 SP1 UC08 | V9.1 SP1 UC08 |
| Siemens/SIMATIC PCS neo V5.0generic | >=0 <* | * |
| Siemens/SIMATIC PCS neo V6.0generic | >=0 <V6.0 SP1 | V6.0 SP1 |
| Siemens/SIMATIC PDM Maintenance Station V5.0generic | >=0 <* | * |
| Siemens/SIMATIC PDM V9.2generic | >=0 <* | * |
| Siemens/SIMATIC PDM V9.3generic | >=0 <V9.3 SP1 Upd2 | V9.3 SP1 Upd2 |
| Siemens/SIMATIC Process Function Library (PFL) V4.0generic | >=0 <* | * |
| Siemens/SIMATIC Process Historian 2020generic | >=0 <* | * |
| Siemens/SIMATIC Process Historian 2022generic | >=0 <* | * |
| Siemens/SIMATIC Process Historian 2024generic | >=0 <V2024 SP1 Upd2 | V2024 SP1 Upd2 |
| Siemens/SIMATIC ProSave V17generic | >=0 <V17 Update 9 | V17 Update 9 |
| Siemens/SIMATIC ProSave V18generic | >=0 <* | * |
| Siemens/SIMATIC ProSave V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/SIMATIC ProSave V20generic | >=0 <* | * |
| Siemens/SIMATIC Route Control V10.0generic | >=0 <* | * |
| Siemens/SIMATIC Route Control V9.1generic | >=0 <* | * |
| Siemens/SIMATIC S7-1500 Software Controller V2generic | >=0 <* | * |
| Siemens/SIMATIC S7-1500 Software Controller V3generic | >=0 <V31.1.5 | V31.1.5 |
| Siemens/SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)generic | >=0 <V4.0.1 | V4.0.1 |
| Siemens/SIMATIC S7 F Systems V6.3generic | >=0 <* | * |
| Siemens/SIMATIC S7 F Systems V6.4generic | >=0 <* | * |
| Siemens/SIMATIC S7-PCTgeneric | >=0 <V3.5 SP4 Update 1 | V3.5 SP4 Update 1 |
| Siemens/SIMATIC S7-PLCSIM Advancedgeneric | >=0 <V7.0 Update 1 | V7.0 Update 1 |
| Siemens/SIMATIC S7-PLCSIM V17generic | >=0 <* | * |
| Siemens/SIMATIC S7-PLCSIM V18generic | >=0 <* | * |
| Siemens/SIMATIC S7-PLCSIM V19generic | >=0 <* | * |
| Siemens/SIMATIC S7-PLCSIM V20generic | >=0 <V20 Update 1 | V20 Update 1 |
| Siemens/SIMATIC Safety Matrixgeneric | >=0 <* | * |
| Siemens/SIMATIC STEP 7 CFC V19generic | >=0 <* | * |
| Siemens/SIMATIC STEP 7 CFC V20generic | >=0 <* | * |
| Siemens/SIMATIC STEP 7 V5.7generic | >=0 <* | * |
| Siemens/SIMATIC Targetgeneric | >=0 <V6.0 SP3 | V6.0 SP3 |
| Siemens/SIMATIC WinCC flexible ESgeneric | >=0 <* | * |
| Siemens/SIMATIC WinCC Runtime Advancedgeneric | >=0 <V17 Update 9 | V17 Update 9 |
| Siemens/SIMATIC WinCC Runtime Professionalgeneric | >=0 <V21 | V21 |
| Siemens/SIMATIC WinCC Runtime Professional V20generic | >=0 <* | * |
| Siemens/SIMATIC WinCC TeleControlgeneric | >=0 <* | * |
| Siemens/SIMATIC WinCC Unified Line Coordinationgeneric | >=0 <V20 | V20 |
| Siemens/SIMATIC WinCC Unified PC Runtime V18generic | >=0 <* | * |
| Siemens/SIMATIC WinCC Unified PC Runtime V19generic | >=0 <* | * |
| Siemens/SIMATIC WinCC Unified PC Runtime V20generic | >=0 <* | * |
| Siemens/SIMATIC WinCC Unified Sequencegeneric | >=0 <V20 | V20 |
| Siemens/SIMATIC WinCC V7.5generic | >=0 <V7.5 SP2 Update 20 | V7.5 SP2 Update 20 |
| Siemens/SIMATIC WinCC V8.0generic | >=0 <V8.0 Update 8 | V8.0 Update 8 |
| Siemens/SIMATIC WinCC V8.1generic | >=0 <V8.1 Update 3 | V8.1 Update 3 |
| Siemens/SIMATIC WinCC Visualization Architect (SiVArc) V17generic | >=0 <V17 Update 9 | V17 Update 9 |
| Siemens/SIMATIC WinCC Visualization Architect (SiVArc) V18generic | >=0 <* | * |
| Siemens/SIMATIC WinCC Visualization Architect (SiVArc) V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/SIMATIC WinCC Visualization Architect (SiVArc) V20generic | >=0 <V20 Update 3 | V20 Update 3 |
| Siemens/SIMIT Rapid Testergeneric | >=0 <* | * |
| Siemens/SIMIT Simulation Platformgeneric | >=0 <* | * |
| Siemens/SINAMICS Startdrive V17generic | >=0 <* | * |
| Siemens/SINAMICS Startdrive V18generic | >=0 <* | * |
| Siemens/SINAMICS Startdrive V19generic | >=0 <* | * |
| Siemens/SINAMICS Startdrive V20generic | >=0 <* | * |
| Siemens/SINEC NMSgeneric | >=0 <V4.0 | V4.0 |
| Siemens/SINEMA Remote Connect Clientgeneric | >=0 <* | * |
| Siemens/SITRANSgeneric | >=0 <* | * |
| Siemens/Standard PID CTRL Toolgeneric | >=0 <* | * |
| Siemens/TeleControl Server Basic V3.1generic | >=0 <V3.1.2.2 | V3.1.2.2 |
| Siemens/TIA Administratorgeneric | >=0 <V3.0.6 | V3.0.6 |
| Siemens/TIA Portal Cloud Connectorgeneric | >=0 <V2.3 | V2.3 |
| Siemens/TIA Portal Test Suite V17generic | >=0 <* | * |
| Siemens/TIA Portal Test Suite V18generic | >=0 <* | * |
| Siemens/TIA Portal Test Suite V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/TIA Portal Test Suite V20generic | >=0 <V20 Update 3 | V20 Update 3 |
| Siemens/TIA Project-Servergeneric | >=0 <V2.2 | V2.2 |
| Siemens/TIA Project-Server V17generic | >=0 <* | * |
| Siemens/Totally Integrated Automation Portal (TIA Portal) V17generic | >=0 <V17 Update 9 | V17 Update 9 |
| Siemens/Totally Integrated Automation Portal (TIA Portal) V18generic | >=0 <* | * |
| Siemens/Totally Integrated Automation Portal (TIA Portal) V19generic | >=0 <V19 Update 4 | V19 Update 4 |
| Siemens/Totally Integrated Automation Portal (TIA Portal) V20generic | >=0 <V20 Update 4 | V20 Update 4 |
| Siemens/WinCC Panel Image Setupgeneric | >=0 <V17 Update 9 | V17 Update 9 |
Published upstream
Aug 12, 2025
Evidence: source:cvelist:source_dates:source-dates:recordSource modified
Aug 11, 2026
Evidence: source:cvelist:source_dates:source-dates:recordFirst seen by HOL
Aug 11, 2026
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
Quoted source text, attributed separately from HOL analysis.