Answer in brief
CVE-2025-40817 records a High severity (CVSS 7.1) vulnerability in CISA ADP Vulnrichment. The current sources do not mark it as known exploited. The current feed maps Siemens/LOGO! 12/24RCE (generic), Siemens/LOGO! 12/24RCEo (generic), Siemens/LOGO! 230RCE (generic), Siemens/LOGO! 230RCEo (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
Analysis pending evidence review
HOL Guard separates source facts from reviewed analysis. See the methodology.
CVSS is 7.1. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.
Analysis status
Analysis pending evidence review
Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.
The current feed maps Siemens/LOGO! 12/24RCE (generic), Siemens/LOGO! 12/24RCEo (generic), Siemens/LOGO! 230RCE (generic), Siemens/LOGO! 230RCEo (generic) and additional mapped packages. Check affected ranges and fixed versions before updating.
| Package | Affected range | Fixed version |
|---|---|---|
| Siemens/LOGO! 12/24RCEgeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/LOGO! 12/24RCEogeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/LOGO! 230RCEgeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/LOGO! 230RCEogeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/LOGO! 24CEgeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/LOGO! 24CEogeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/LOGO! 24RCEgeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/LOGO! 24RCEogeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/SIPLUS LOGO! 12/24RCEgeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/SIPLUS LOGO! 12/24RCEogeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/SIPLUS LOGO! 230RCEgeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/SIPLUS LOGO! 230RCEogeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/SIPLUS LOGO! 24CEgeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/SIPLUS LOGO! 24CEogeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/SIPLUS LOGO! 24RCEgeneric | >=0 <V1.84.05 | V1.84.05 |
| Siemens/SIPLUS LOGO! 24RCEogeneric | >=0 <V1.84.05 | V1.84.05 |
Published upstream
Nov 11, 2025
Evidence: source:cvelist:source_dates:source-dates:recordSource modified
Oct 13, 2026
Evidence: source:cvelist:source_dates:source-dates:recordFirst seen by HOL
Oct 13, 2026
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently.
Quoted source text, attributed separately from HOL analysis.