Answer in brief
CVE-2026-100688 records a High severity (CVSS 7.1) vulnerability in Budibase server before 3.45.0 Cross-Tenant Information Disclosure. The current sources do not mark it as known exploited. The current feed maps budibase/server (generic). Check affected ranges and fixed versions before updating.
Analysis pending evidence review
HOL Guard separates source facts from reviewed analysis. See the methodology.
CVSS is 7.1. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.
Analysis status
Analysis pending evidence review
Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.
The current feed maps budibase/server (generic). Check affected ranges and fixed versions before updating.
| Package | Affected range | Fixed version |
|---|---|---|
| budibase/servergeneric | >=0 <3.45.0 | 3.45.0 |
Published upstream
Sep 26, 2026
Evidence: source:cvelist:source_dates:source-dates:recordSource modified
Sep 26, 2026
Evidence: source:cvelist:source_dates:source-dates:recordFirst seen by HOL
Sep 26, 2026
Budibase server before 3.45.0 contains a cross-tenant information disclosure vulnerability in the GET /api/applications/:appId/appPackage endpoint that allows authenticated users to read another tenant's application metadata and source code. Attackers can supply a victim tenant's app id to retrieve sensitive application details including navigation structure, role names, internal screen URLs, JavaScript snippets, and user identifiers without authorization checks.
Quoted source text, attributed separately from HOL analysis.