Answer in brief
CVE-2026-105279 records a Critical severity (CVSS 9.3) vulnerability in J4Care dcm4che Missing Authentication for Critical Function. The current sources do not mark it as known exploited. The current feed maps J4Care/dcm4chee-arc-light (generic). Check affected ranges and fixed versions before updating.
Analysis pending evidence review
HOL Guard separates source facts from reviewed analysis. See the methodology.
CVSS is 9.3. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.
Analysis status
Analysis pending evidence review
Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.
The current feed maps J4Care/dcm4chee-arc-light (generic). Check affected ranges and fixed versions before updating.
| Package | Affected range | Fixed version |
|---|---|---|
| J4Care/dcm4chee-arc-lightgeneric | 5.35.1 | Not reported |
Published upstream
Oct 16, 2026
Evidence: source:cvelist:source_dates:source-dates:recordSource modified
Oct 16, 2026
Evidence: source:cvelist:source_dates:source-dates:recordFirst seen by HOL
Oct 16, 2026
In the default configuration, the archive accepts DICOM associations from an unregistered calling AE. A remote peer can use C-FIND and C-GET to enumerate and retrieve patient information and medical images. It can also use C-STORE to file fabricated study content under an existing patient identity.
Quoted source text, attributed separately from HOL analysis.