Answer in brief
CVE-2026-50062 records a High severity (CVSS 7.8) vulnerability in CISA ADP Vulnrichment. The current sources do not mark it as known exploited. The current feed maps Siemens/Solid Edge SE2025 (generic), Siemens/Solid Edge SE2026 (generic). Check affected ranges and fixed versions before updating.
Analysis pending evidence review
HOL Guard separates source facts from reviewed analysis. See the methodology.
CVSS is 7.8. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.
Analysis status
Analysis pending evidence review
Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.
The current feed maps Siemens/Solid Edge SE2025 (generic), Siemens/Solid Edge SE2026 (generic). Check affected ranges and fixed versions before updating.
| Package | Affected range | Fixed version |
|---|---|---|
| Siemens/Solid Edge SE2025generic | >=0 <V225.0 Update 15 | V225.0 Update 15 |
| Siemens/Solid Edge SE2026generic | >=0 <V226.0 Update 7 | V226.0 Update 7 |
Published upstream
Aug 11, 2026
Evidence: source:cvelist:source_dates:source-dates:recordSource modified
Aug 12, 2026
Evidence: source:cvelist:source_dates:source-dates:recordFirst seen by HOL
Aug 11, 2026
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
Quoted source text, attributed separately from HOL analysis.
Answer in brief
CVE-2026-50062 records a High severity (CVSS 7.8) vulnerability in CISA ADP Vulnrichment. The current sources do not mark it as known exploited. The current feed maps Siemens/Solid Edge SE2025 (generic), Siemens/Solid Edge SE2026 (generic). Check affected ranges and fixed versions before updating.
Analysis pending evidence review
HOL Guard separates source facts from reviewed analysis. See the methodology.
CVSS is 7.8. The current sources do not mark it as known exploited. Treat this as a source-backed prioritization signal, not a statement about your environment.
Analysis status
Analysis pending evidence review
Factual feed record only; HOL analysis is not approved for indexing. Read the methodology.
The current feed maps Siemens/Solid Edge SE2025 (generic), Siemens/Solid Edge SE2026 (generic). Check affected ranges and fixed versions before updating.
| Package | Affected range | Fixed version |
|---|---|---|
| Siemens/Solid Edge SE2025generic | >=0 <V225.0 Update 15 | V225.0 Update 15 |
| Siemens/Solid Edge SE2026generic | >=0 <V226.0 Update 7 | V226.0 Update 7 |
Published upstream
Aug 11, 2026
Evidence: source:cvelist:source_dates:source-dates:recordSource modified
Aug 12, 2026
Evidence: source:cvelist:source_dates:source-dates:recordFirst seen by HOL
Aug 11, 2026
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All versions < V226.0 Update 7). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
Quoted source text, attributed separately from HOL analysis.